IRIS 3.2.3

Important! You must have OS administrator privileges to upgrade the IRIS software.

Program files are saved in the following locations (which required read/write permission):

  1. Main installation folder for IRIS software
  2. …\Windows\System32
  3. …\Program Files\Common Files\medi.com
  4. Additionally Windows registry is modified.

Upgrading to the new IRIS version is a process that can not be undo later, so please read the following changes carefully and accept any inconvenience.

2019-08-13 (Version 3.2.3.36) – Available after tests 2019-08-16

  1. Footswitch – support for type A (Win 7. Win 10) and new B (Win 10, latest updates)
  2. CANON EOS SDK – Add support for Canon EOS 200D.
  3. eZLA – Update the release module to version 2019/07 (bug fixes).
  4. Other minor bugs have been fixed.

2019-06-24 (Version 3.2.3.35) – Available after tests 2019-07-23

  1. IRIS Service (medicom service) – problems with server communication have been resolved.
  2. Displays the complete description of the ICD10 code. Added in modules: Certificate – information for the referring physician,
  3. Endoscopy, One-day Hospitalisation, Ophthalmology Form, NFZ settlements, Referral. It was possible to switch this functionality on and off. It is enabled by default.
  4. Invoices – improvement in saving invoice items for the centre (there was an error when there was no record in the database).
  5. New installation with a clean database (the eZLA module in the Polish language version added by default).
  6. Other minor bugs were fixed.

2019-06-10 (Version 3.2.3.34) – made available after tests 2019-06-17

“.

  1. LinkView 1200 – Add support for the new gravebe.
  2. PC Checking – Extend the list of processors compliant with IRIS requirements.
  3. IRIS Service (medicom service) – Add logs and reconnect when the module is disconnected.
  4. Backup module – fix a problem when the submodule disconnects and add logs.
  5. IRIS Settings – Adding an email field to a window and personnel list.
  6. Displays the full description of the ICD10 code. Added in modules: Certificate – information for the referring physician, Endoscopy, Day Hospital, Ophthalmology Form, NFZ settlements, Referral.
  7. Other minor mistakes were corrected.

2019-05-10 (Version 3.2.3.33) – made available after tests 2019-05-27

“.

  1. Directions – new universal and fully configurable directories for research have been added.
  2. eZLA – update of the dismissal module to version 2019/05 (loading the dismissal history for the “care” dismissal type) – the module cooperates with the electronic dismissal platform (digital signature required).
  3. Support for the new Game Capture HD60 grabber.
  4. Prescriptions – improvement of the print example.
  5. Other minor errors have been fixed.

2019-04-17 (Version 3.2.3.32) – made available after tests 2019-04-24

“.

  1. Prescriptions – changes concerning the issuing person in accordance with the regulation of 13.04.2019.
  2. Invoices – numbering changes (monthly/annual) were only xx/XX/201X. Now we have the choice: xx/XX/201X or xx/mm/XX/201X.
  3. eZLA – update of the exemption module to version 2019/04 – the module cooperates with the electronic exemption platform (digital signature required).
  4. Documents in Cloud (http://documentsincloud.com) – a collection of amendments.
  5. Other minor bugs have been fixed.

2019-02-06 (Version 3.2.3.31) – Available after tests 2019-03-20

  1. Documents In Cloud (http://documentsincloud.com) – added cooperation with the portal and the ability to sign documents on the tablet.
  2. NFZ – possibility of importing new agreements (updated in 2019)
    eZLA- update of the exemption module to version 2019/02 – the module cooperates with the electronic exemption platform (digital signature required).
  3. eZLA – added logging of operations and facilitation of A and D codes.
    Added checking of system requirements during application launch.
  4. Referrals – added the ability to use longer test names for his-pat referrals.
  5. Fixed the installer (the process of uninstalling the application).
  6. Other minor bugs have been fixed.

2018-11-26 (Version 3.2.3.30) – made available after tests 2018-11-30

.

  1. eZLA – update of the exemption module to version 2018/12 – the module cooperates with the electronic exemption platform (digital signature required).
  2. Footswitch – improvement of operations.
  3. Other minor bugs have been fixed.

2018-06-06 (Ver. 3.2.3.28) – available after validation on 2018-06-19

  1. GDPR – new statements necessary for work.
  2. Support for the OCT Copernicus Revo device has been added.
  3. DHClient software – problem with adding new patients was fixed.
  4. Other minor bugs were fixed.

2018-03-19 (Ver. 3.2.3.27) – available after validation on 2018-03-22

  1. GDPR – minor problems on the patient’s printouts.
  2. Icons with devices – fixed bug with remembering and displaying.
  3. Other minor bugs were fixed.

2017-12-22 (Wersja 3.2.3.26) – udostępniona po testach 2018-02-10

  1. Endoscopy – adding the ability to change the camera on existing visits for all members of the Administrators group (not just the primary “Admin” user).
  2. RC/SL and others – automatic calibration of new images – the possibility to set default calibration parameters for the selected device (camera) has been added.
  3. Update modules for CANON cameras.
    • Update SDK CANON EOS to version 3.6.30.
    • Manuals were updated for 1300D camera.
  4. Support for the Leisegang videocolposcope with “Point Grey Camera”.
  5. Support for Blackmagic cards.
    • Extension of FPS settings with values of 40 and 50 FPS for the new Blackmagic grabber.
    • Message about the need to change the compressor.
  6. Universal module for downloading images and reports from any remote device – NEW!.The most important features:
    • possible communication with the device via WiFi.
    • configuration via internal FTP server.
  7. HL-7 – bug fixing. The most important fixed problems:
    • HL-7 Settings -> “external IRIS services” window – problem with deleting has been removed.
    • Improving the login system and removing the problem with entries longer than 500 characters.
    • Removing a problem with the OBX.16 field – it may have one less nesting after the change.
  8. Camera devices -> Settings – type of photos “without changes” automatically blocked image modifications – added information on the screen why it is like that.
  9. DICOM Import – after installing new images are added to an existing visit by default.
  10. Other minor bugs were fixed.
  11. All changes released earlier in the ver. 3.2.3.25 – update1, update2 and update3.

2017-11-06 (Ver. 3.2.3.25 – update3) – available for selected customers

  1. Support for DinoLite camera for microscopes and other devices.
  2. Other minor bugs were fixed.

2017-08-28 (Ver. 3.2.3.25 – update2) – available for selected customers

  1. HL-7 – new functionalities.The most important changes in this module:
    • Automatic filling “sending form” with default data.
    • Prevent sending data without a completed “sending form”.
    • New option to send images (reports) as: URL^Image in the OBX.3 field.
    • New option to disable the sending of R and M characters in OBX.4 (instead of it the number is sent).
    • Support for new type of OBX segment with data about the ICD9 procedures.
    • Support for sending files as BASE64.
  2. Other minor bugs were fixed.

2017-07-31 (Ver. 3.2.3.25 – update1) – available for selected customers

  1. CANON EOS SDK – support for Canon EOS 1300D.
  2. Other minor bugs were fixed.

2017-03-26 (Ver. 3.2.3.25) – available after validation on 2017-07-15

  1. Automatic backup for database and all data (requires additional license).
  2. Archive functionality have been updated and separated (now available in IRIS Settings).
  3. IRIS Ophthalmology – support for new Perimeter devices.New devices were added:
    • Optopol PTS 920 and 925 series and newest.
    • Optopol PTS 1000 and 2000 series and newest.
    • Any device started with command line where examination report is exported on the end.
  4. General interview and USG obstetric examination were modified.
  5. Other minor bugs were fixed.

2017-03-09 (Ver. 3.2.3.24) – available after validation on 2017-03-22

  1. Support for DVI2USB and WebCam video cards.
  2. IRIS Endoscopy – support for new washer machines via COM.
  3. Printing (print settings) – fixed problem with printing on the wrong paper size.
  4. Improved problem for small thumbnail creation when the thumbnail panel height was reduced.
  5. Other minor bugs were fixed.

2016-10-21 (Ver. 3.2.3.23) – available after validation on 2016-10-31

  1. Support for Canon EOS 760D with Live View was added.
  2. SDK for all Canon cameras was updated to version 3.5.0 (Windows 7/8.1/10).
  3. IRIS Endoscopy – English version was added for examination form.
  4. IRIS Schedule – minor bugs were fixed (refreshing current view for rooms).
  5. IRIS Settings – added possibility to remove the password for other users by user with the appropriate permissions.
  6. Other minor bugs were fixed.

2016-08-31 (Ver. 3.2.3.22) – available after validation on 2016-09-30

  1. IRIS RC/SL – support for DICOM functionality was added.
  2. DICOM – support for Worklist via TCP/IP was added (communication with DICOM PACS).
  3. DICOM – support for lossless compression was added.
  4. DICOM – support for automatic export images was added with “only key images” option.
  5. IRIS Endoscopy – fixed problems with the blocking of the head.
  6. IRIS Schedule – optimization of communication with database.
  7. IRIS Schedule – new privileges to block planned terms and remove blockers.
  8. Referral for examination – new was added for histopathology.
  9. Referral for examination – number of the register book was added.
  10. NHF – automatic checking if the patient is insured.
  11. XP compatibility mode and run as an administrator is now cleared for the main EXE file during installation. It is no needed any more.
  12. Other minor bugs were fixed.

2016-07-31 (Ver. 3.2.3.21)

  1. NHF – set of changes to keep better communication with Poland NHF.
  2. HL-7 – set of changes to integrate with Polish Kamsoft system.
  3. Support for DVI2USB 3.0 grabber (correct resolution according to the specification).
  4. The ability to display Patient list for today (schedule) and the list of all patients at the same time on the screen (Specialisation and Assistant).
  5. DICOM – common settings for DICOM output (one for the station, and not for each user).
  6. Polish manuals have been updated.
  7. Other minor bugs were fixed.

2016-06-06 (Ver. 3.2.3.20)

  1. DICOM – added possibility to configure many types of export (output) to the DICOM file (*.DCM).
  2. DICOM – Fixed problems with export to a DICOM file in the IRIS RC/SL Software.
  3. Security – log-in module has been extended to a wide list of configurable rules to define passwords and enhance security. The three main areas are described below:a) Password strength:
    • Can be defined a minimum password length.
    • Can be defined the number of uppercase and lowercase characters.
    • Can be defined obligation to use numbers and special characters.

    b) Log-in:

    • Password expiration can be set.
    • Reminder to change the password can be set.
    • Blocking recent passwords can be set.
    • The maximum number of attempts can be set.

    c) Additionally, administrator can set the time after which the user is automatically logged out.

    New functionality is available in the IRIS Settings in the “Security” part.

  4. NHF (polish market) – added the ability to communicate with external systems (Kamsoft). Cooperation is possible by:
    • Export list of users to CSV file accepted by Kamsoft.
    • Export list of patients to CSV file accepted by Kamsoft.
    • Export list of examinations (counted by NHF) to CSV file accepted by Kamsoft.

    New functionality is available in the IRIS Administration in the “Export data” part.

  5. Other minor bugs were fixed.

2016-05-24 (Ver. 3.2.3.19)

  1. RC/SL – Planimetry measurements saving problem was fixed.
  2. Other minor bugs were fixed.

2016-03-31 (Ver. 3.2.3.18)

  1. Upgrading the error reporting system (Eurekalog).
  2. IRIS Ophthalmology – improvement for saving settings for patient list and examination list wide.
  3. IRIS Administration – NHF examinations – minor bugs were fixed (only polish market).
  4. IRIS Settings – translations for polish language were updated (only polish market).
  5. Update ICD-10 codes for the range F.10 to F.19 (only polish market).
  6. Changes for silent retinal camera and slit lamp modules. Now IRIS software is able to download images and PDF reports saved in new examination directory (e.g. “Exchange folder\2015-12-29 Kowalski”). New option is available in the module settings.
  7. Other minor bugs were fixed.

2016-02-29 (Ver. 3.2.3.17)

  1. HL-7 module – new message during visit is closing to remember about sending order to HIS.
  2. HL-7 module – large set of improvements in communication. The most important:
    • Added message about the change of patient data ADT^A31
    • Added message about adding the patient ADT^A28
    • Added message about removing the patient data ADT^A29
    • Added ability to disable prefixing directory with \\
    • Description for OBX.3 was extended for the report format like “URL^Image”
    • Send links to the PDF/Images as File:/// URL
    • Send CA Acknowledgement (instead AA)
    • Log on unsuccessful all data from incoming HL7 message
    • Now DG1 segments must be at the end of the HL7 message
    • The ADT message type is now read from the header (not from ENV.2)
  3. Endoscopy – performance improvements when reading the list of heads.
  4. Endoscopy – added the ability to manually cleaning the heads.
  5. IRIS Service (windows service) – fixed error when stopping the service, increased safety.
  6. Set of changes for improvement application performance.
  7. Added support for LGP Stream Engine grabber.
  8. Other minor bugs were fixed.

2016-01-18 (Ver. 3.2.3.16)

  1. Foot switch – faster and more convenient. Now using the foot switch, you can open the Camera/Video module and faster start examination.
  2. HL-7 module – support for other code pages for messages sent from IRIS to HIS. Now it is configurable and can be selected from:
    • ASCII (no polish characters)
    • Win 1250 (for polish market)
    • UTF8
    • UTF16
  3. HL-7 module – adding the ability to enable and disable prefix for paths using characters “\\”.
  4. Added support for AVerMedi C875 Capture grabber.
  5. Other minor bugs were fixed.

2015-12-29

  1. Update ICD-9 codes (only polish market).
  2. Update ICD-10 codes for the range F.10 to F.19 (only polish market).
  3. Changes for silent retinal camera and slit lamp modules. Now IRIS software is able to download images and PDF reports saved in new examination directory (e.g. “Exchange folder\2015-12-29 Kowalski”). New option is available in the module settings.
  4. Other minor bugs were fixed.

2015-10-06

  1. Firebird 2.1.7 x64 is supported.
  2. HL-7 module – support for new messages were added, a lot of communication problems were resolved.
  3. HL-7 module – support for patients without PatientID (using HIS ID).
  4. Endoscopy – clinic centre and doctor are import automatically from HL-7 order.
  5. Endoscopy – support for bar code reader.
  6. Endoscopy – new field with recommendations.
  7. Reports – Visit doctor name in the examination/visit headers was added.
  8. SMS module – now “copy” and “paste” is available for edited messages.
  9. Installation on Windows 10 is available (set of problems).
  10. Other minor bugs were fixed.

2015-08-27

  1. HL-7 module – support for new messages were added, support for OBX were added (step 2).
  2. IRIS RC/SL – adding automatic calibration for camera images.
  3. Other minor bugs were fixed.

2015-07-21

  1. Adding support for new washers endoscopic.
  2. HL-7 module – support for new messages were added (step 1).
  3. Angiography description – fix the problem with this arrow key.
  4. EWUŚ – Renaming fields to comply with the NFZ. Improved test connection.
  5. Other minor bugs were fixed.

2015-05-30

  1. EWUŚ – checking the status of the patient in the NHF was added (only polish localization).
  2. Other minor bugs were fixed.

2015-04-26

  1. HL-7 module – Diagnosis is sent in the ORM^O01 message.
  2. HL-7 module – Translations were updated in the settings window.
  3. HL-7 module – New silent logs were added.
  4. SMS/Email module – name of day of week can be added (Monday, Tuesday, etc.).
  5. MotionJPEG is supported for the UC-21 videocolposcope.
  6. Libraries for HD AVerMedia video cards were updated.
  7. Patients on the patient list can have different colours for VIP (green), ATT(red), etc. It is possible to add own status with different colours.
  8. Disease History – user can filter printout by leading doctors.

2015-03-18

  1. Support for Canon 50D and 70D with Live View were added.
  2. Support for Canon 100D without Live View was added.
  3. SDK for all Canon cameras was updated to version 2.15 (now it works only on Windows 7 or higher).
  4. Bug for fast switching camera profiles was fixed (5898).
  5. Problem with loading device serial number was fixed (now several Canon cameras can work in parallel correctly – e.g. two 50D).
  6. Support for new HD AVerMedia video cards was added (including USB 3.0 external cards).
  7. Loading *.mp4 files from external devices and conversion to the internal format were added.
  8. Other minor bugs and manuals were updated.

2015-01-18

  1. Logo, name and address were changed for the medi.com Sp. z o.o. company.
  2. Update process was fixed. Now it works correctly on Windows 7/8 without disabling UAC.
  3. IRIS Server software was updated. Now it works correctly on Windows 7/8 without disabling UAC.
  4. Remote assistance (TV) was updated to the newest version.
  5. Other minor bugs and manuals were updated.

2014-07-30

Please see polish changelog page https://www.medi.com.pl/aktualizacje/ or write on office@medi.com.pl.

2014-04-17

Please see polish changelog page https://www.medi.com.pl/aktualizacje/ or write on office@medi.com.pl.

2013-01-31

Please see polish changelog page https://www.medi.com.pl/aktualizacje/ or write on office@medi.com.pl.

2012-12-24

Please see polish changelog page https://www.medi.com.pl/aktualizacje/ or write on office@medi.com.pl.

2012-10-23

Please see polish changelog page https://www.medi.com.pl/aktualizacje/ or write on office@medi.com.pl.